Evaporator Model Number CE 063 J AY 18 R Motor HP (X10) Impeller Type: J or K Impeller Size:060= 6.0" 063= 6.3" Gear Ratio (see Gears table for list) Compressor Model Number Compressor Type: CE= Centrifugal Hermetic PE 200 Unit Model Number Unit Type: PE- a single compressor, hermetic centrifugal chiller. Nominal Tonnage Unit Voltage N=200/60/3 ...

Mcquay model number tonnage. Things To Know About Mcquay model number tonnage.

be seen that a Model MC216 UI1it will deliver 6550 CFM with a fan outlet velocity of 1605 FPM and that the cooling coil face velocity will be 500 FPM. 2. From the General Specifications Table on Page 11 it is found that the maximum number of zones is 12 for a Model MC216 unit. Each available zone in a McQuay Multi-Zone unitI need to know the tonnage rating for a McQuay Model WSC087BAAA style E733329010 chiller. The SN is STNU020400172. Can - Answered by a verified HVAC Technician. We use cookies to give you the best possible experience on our website. ... I have a number (22 units - total) of overhead and wall Hydronic Boiler fed heating units that were damaged ...McQuay chillers m# PEH079 S# 5YC0100700 style 0547362010 m# PEH076 S# 5ZA81012-01 style 9566323018 trane screw centravac m# RTHA130FCMONDUC3LF2LFNN00GUQ S# U90K03031 device# 3036RT130 appreciate it building engineer would like something more than a shoot from the hip nominal tonnage.HVAC BRAND MODEL NUMBER NOMENCLATURE. Select one of the drop-down lists below. that corresponds to the FIRST letter. of your HVAC brand name. Then make your selection from the list. HVAC - A. HVAC - B. HVAC - C. HVAC - D.This Used McQuay 100 Ton Air Cooled Chiller has been inspected and is located in our facility in Bridgeport, Tx. This machine has sold. View more machines. McQuay AGZ: Product Document ... Model Number: AGZ100; Year: 2011; 100 Tons Nominal Cooling; 460V/3Ph/60Hz; Refrigerant: R-410a;

Daikin RoofPak applied packaged rooftop systems, from 15 to 150 tons, are the ideal solution for your one to eight-story building projects. Available in air-cooled and evaporative-cooled models, they combine the lower installation costs and interior space savings of a roof-mounted system with the operating and maintenance efficiencies of ... York HVAC Model Number Name Decoding Guide. YORK HVAC EQUIPMENT NOMENCLATURE GUIDE - DECODE the PRODUCT NUMBER found on the EQUPMENT DATA TAG. CLICK ANYWHERE on THIS PAGE to RETURN to YORK HVAC Information at InspectApedia.com. z Z z a z zoa g z Z 33 00 < z 88 o o z < e a 2 z o. W x.

I need to know the tonnage rating for a McQuay Model WSC087BAAA style E733329010 chiller. The SN is STNU020400172. Can - Answered by a verified HVAC …Can you tell me the efficiency in kW/Ton of a McQuay chiller model PEH100-BCBB? Contractor's Assistant: ... You are right that the efficiency of a McQuay chiller may be plus or minus 30% and there are a number of factors contributing to this. ... Please I need the information about McQuay model PEH087 year 1995 with 134A refrigerant and 500 ...

Aug 10, 2023 · The tonnage of an AC unit can typically be determined from the model number by looking for a number that is divisible by 12. For example, if the model number is ABC12345, and the number 36 appears in the middle of the model number (e.g., ABC36 12345), then the AC unit is likely a 3-ton unit, since 36 is divisible by 12. Depending on which Whirlpool appliance, the model number can be easily found on the inside surface of the appliance. The model numbers are generally found inside the drawer or on t...Pathfinder Model AWV chillers with an integrated system of waterside economizer coils may be able to satisfy 100% of cooling load without starting a compressor. Through a set of valves, the chiller will automatically control where the fluid from the load is directed to achieve optimal system eficiency.Lower unit: Model WDC 126, 2000 ton, dual compressor chiller *ETL applies to WSC, WDC, WCC, HSC, HDC only Manufactured in an ISO Certified Facility ©2009 McQuay International. Illustrations and data cover the McQuay International product at the time of publication and we reserve the right to make changes

To determine the AC tonnage from a Carrier model number, locate the two digits following the first letter in the model sequence. These two numbers typically represent the BTU capacity in thousands, with one ton equivalent to 12,000 BTUs. Understanding the tonnage of your Carrier air conditioning unit is crucial for ensuring optimal efficiency ...

Refrigerant-side maximum working pressure is 200psig. Water-side is 150 psi (1034 kPa) with 300 psi (2068 kPa) available as an option. Approximate total square footage of insulation surface required for individual packaged chillers is tabulated by evaporator code and can be found below. The suction.

Model Number: AM000013. Description Reviews (0) * McQuay * 60 Ton System * Water Cooled * Model WGZ060AW27-ERIO * Full Controls * Year of Mfg. 2002 * Approximate Foot Print: 9' x 4' x 5' Reviews There are no reviews yet. Be the first to review "Chiller - 60 Ton McQuay 2002" Cancel reply. You must be logged in to post a review. Basically all manufacturers encode the size or tonnage of their systems into the model number. Tonnage is a measure of BTU’s in 12,000 BTU increments. For example a 1 ton system would have 12,000 BTU’s. A 2.5 ton system would have 30,000 BTU’s. These are reflected in the model numbers near the middle and often followed by a letter. Model MPS. Maverick® I packaged rooftop systems, from 3 to 25 tons, are designed from the ground up to include the features and benefits that are ideal for offices, schools, libraries, and strip malls. They combine the lower installation costs and interior space savings of a roof-mounted system with the operating and maintenance efficiencies ...For demanding filtration, Daikin's custom air handler unit provides advanced filtration with HEPA, PCO, gas phase, and low pressure filters. They also help you achieve higher indoor air quality by using ultra-violet lights, stainless steel drain pans, and anti-microbial liner options. 003-169 Unit Sizes. 900 to 129,000 CFM.Find the most common problems that can cause a Mcquay Air Conditioner not to work - and the parts & instructions to fix them. Free repair advice! En español. 1-800-269-2609 24/7. Track Order. ... Need help finding your model number? or. Let Us Diagnose The Problem. Select “Common Problems” below and we’ll help you discover the cause of ...McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL. 103 - 228 Vintage C. LML, LSB. 106 - 111 Vintage E Last Manufactured: 1999. To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com. Replacement Parts List No. 055222600 Revision G 12/2019. consistent with the McQuay rooftop line. Expanded flexibility along with the availability of the state-of-the-art, MicroTech direct digital control (DDC) system on the RDS 800C and 802C makes the RDS unit the ideal selection in rooftop air handlers. Lower installation costs The McQuay RoofPak air handling unit arrives on the job site

model on 6 ton •Single circuit, 2-stage cooling mod-els are available from 7.5 to 10 ton. •Dual circuit, 2-stage cooling stage models are available from 7.5 to 15 ton. •EERs up to 11.3 with IEERs up to 13.0 •Staged Air Volume (SAV™) 2-speed indoor fan motor system automati-cally adjusts the indoor fan motorManuals and User Guides for McQuay MLC040C. We have 4 McQuay MLC040C manuals available for free PDF download: Installation Manual McQuay MLC040C Installation Manual (96 pages)NOTE: ARI limit for certification on 60 Hz service is 2,000 tons. McQuay dual compressor chillers with or without VFD are available up to 2,700 tons. The chart below illustrates the relative IPLV efficiencies of various McQuay options for a 500 ton selection. The chiller cost increases as the efficiency improves. Industry Leading Efficiencies ...McQuay was founded in the United States in 1933 and has been supplying and servicing equipment for air conditioning, heating and ventilation systems, as well as manufacturing radiators and heat exchangers. ... I also don't have the full model number on the sticker so its difficult to find. Anything will help thank you! chad M/N - LCA150 SM S/N ...Equipment Description. Used McQuay ACR070A827-ER10 Air Cooled Water Chiller with: Air cooled water chiller unit. Maximum relief pressure: 450 PSIG. High side design pressure: 450 PSIG. Low side design pressure: 150 PSIG. Refrigerant: 22. Total charge: 20 pounds. Circuit 1 charge: 60 pounds.A ton of air conditioning equals 12,000 BTU, and 48 divided by 12 equals 4, so the data plate below indicates the system is 4 tons. Here's a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. If you are unsure whether you have found the right two ...Basically all manufacturers encode the size or tonnage of their systems into the model number. Tonnage is a measure of BTU’s in 12,000 BTU increments. For example a 1 ton system would have 12,000 BTU’s. A 2.5 ton system would have 30,000 BTU’s. These are reflected in the model numbers near the middle and often followed by a letter.

Refrigerant-side maximum working pressure is 200psig. Water-side is 150 psi (1034 kPa) with 300 psi (2068 kPa) available as an option. Approximate total square footage of insulation surface required for individual packaged chillers is tabulated by evaporator code and can be found below. The suction.Please consult McQuay Sales Representative for specific availability. McQuay WSHP Product Nomenclature WCMS 1009 E Z Product Category W = WSHP Product Identifier See box below Design Series 1 = A Design 2 = B Design 3 = C Design 4 = D Design 5 = E Design Nominal Capacity 007 = 7,000 009 = 9,000 012 = 12,000 015 = 15,000 019 = 19,000 etc ...

%PDF-1.6 %âãÏÓ 1371 0 obj > endobj 1386 0 obj >/Filter/FlateDecode/ID[2C57F1C273E3CA498FA7F38C6B63FC5F>]/Index[1371 126]/Info 1370 0 R/Length 97/Prev 1518284/Root ...Part Number: 331374601 Effective: March 2008 Supersedes: December 2007 Water-Cooled Centrifugal Chiller ... The McQuay Model WMC Centrifugal Water Chillers are complete, self-contained, automatically controlled, fluid-chilling units featuring oil-free, magnetic bearing compressors. Each unit is completely assembled andMcQuay International Re-Manufactured Screw Compressor. Model: SAL155QA10DA. Capacity: 60 tons using Freon, only. ... 60 Ton. Sold Out. Roll over image to Zoom OR Click for full Gallery (images, video, data sheets) ... McQuay; Model: SAL155QA10DA; Serial Number: 55GR7061-10; Package Details. Screw Compressor Details. Micro Panel Details.Gives number of compressors in unit. Thirteenth Digit Type of Heat: B. Hot water Boiler w/ Cooling C. Cooling Only D. Gas Duct Furnace E. Electric Heater F. Direct Fired Gas Burner H. Hot Water Coil M. High Turndown Power Burner P. Power Burner S. Steam Coil T. Tubular Gas Heater X. None Fourteenth Digit Heating Medium N. Natural Gas O. Oil P ...Air Handlers. Subcategory. Air Handlers. View All. Used McQuay approximately 15 - 20 Ton, 2000 to 6000 CFM. model RDS708BY air conditioning unit. Overall Dimensions 68" wide x 52" high. 5 HP Evaporator fan motor. All loads 460 volt. S/N FB0402030023603. Stock#20667.Model WME 400 to 700 tons (1400 to 2461 kW) 3/60/460 HFC-134a. ... ©2012 McQuay International. Illustrations and data cover the Daikin McQuay product at the time of publication and we reserve ... tonnage range - as low as 0.312. (See page 6 for IPLV definition and discussion). There is a potential for significant energy savings at part load ...McQuay R-410A condensing units are available with EERs that exceed ASHRAE 90.1-2004. R-407C inevitably forces the unit to be significantly less efficient or more expensive, while R-410A reduces energy costs. R-410A refrigerant components are always evenly mixed, which is not true for R-407C.How To Read The Models 60Hz Top-discharge Condensing Unit 4-way Cassette Indoor Unit. 02 01 03 05 07 10 11 Floor & Celling Indoor Unit Air handling Unit ... Condensing …

900 to 100,000 CFM. Seismic Certification. Flexibility. Indoor Air Quality. Operating Efficiency. Easy, Low Cost Installation. Easy Maintenance and Serviceability. Demands for improved IAQ, low sound, high efficiency, and smaller mechanical rooms require a better indoor air handler. Meet Daikin's Vision air handling unit.

Discover McQuay Latam % Minisplits portafolio and the exclusive technologies for your home, small office or smb

Enjoy the convenience of decoding multiple units simultaneously with our batch lookup tool. We are currently working on a model number decoder where we can bring you vital unit specifications based on model number. This information portal is put together by a few enthusiasts with the goal to remove friction for HVAC technicians and professionals.Daikin McQuay Packaged System Nominal capacity 006 = 6 tons 007 = 7.5 tons 010 = 10 tons 012 = 12 tons Design vintage A = Vintage 1. Cooling efficiency. H = High (exceeds ASHRAE 90.1) Line voltage 2 = 208 volt power supply 3 = 230 volt power supply 4 = 460 volt power supply 5 = 575 volt power supply Heat medium Y = None (cooling only) G ...FT TOP THEMES ETF MODEL 2 F CA- Performance charts including intraday, historical charts and prices and keydata. Indices Commodities Currencies StocksMcQuay Air Conditioning plant with over 450,000 square feet of manufacturing space - located in Auburn, New York Horizontal (Ceiling) Water Source Heat Pumps – Sizes 007-070 (1/2 to 6 Tons) Model CRH (Standard Range: 55°F to 110°F) Model CRW (Extended Range/Geothermal: 25°F to 110°F) More than 40 years ago, McQuay designed the firstMcQuay Air Conditioning plant with over 450,000 square feet of manufacturing space - located in Auburn, New York Horizontal (Ceiling) Water Source Heat Pumps - Sizes 007-070 (1/2 to 6 Tons) Model CRH (Standard Range: 55°F to 110°F) Model CRW (Extended Range/Geothermal: 25°F to 110°F) More than 40 years ago, McQuay designed the firstComprehensive 3-12.5 Tons offerings in three platforms. Johnson Controls Series 5 3-6 Tons. Delivers simplicity and performance that give you an advantage on almost every rooftop project. Johnson Controls Core 3-12.5 Tons. Economical, go-to product for new construction and replacement. Johnson Controls Pro 3-12.5 Tons.Model"GOV" Size 04-15 DOAS. Model "GOV" Size 04-15 100% Outdoor Air Water Source Heat Pump Specifications 10/06. Unit Specifications. Model "GOV" Size 20-30 DOAS. Model "GOV" Size 20-30 100% Outdoor Air Water Source Heat Pump Specifications 10/06. Unit SpecificationsCatalog 1108- McQuay Efinity Horizontal Water Source Heat Pumps Page 3 of 76. Enfinity Horizontal Ceiling Water Source Heat Pumps Sizes 007-070 (1/2 to 6 Tons) ModelWCCH(StandardRange:55°Fto110°F) Model WCCW(GeothermalRange:30°Fto110°F) McQuay Enfinity Horizontal Ceiling units are designed for use in multiple floor apartments, office ...Controls Integration. Easily integrate with the BAS of your choice by using MicroTech® III controls. The RoofPak air handler unit has become the preferred HVAC solution for thousands of building projects involving air handlers. This is due to decades of innovation, flexibility, durable construction, low capital and operating costs.View and Download McQuay RPS installation and maintenance manual online. RPS air handlers pdf manual download. Also for: Rdt, Rfs, Rcs.McQuay 6- to 10-ton horizontal units have a common cabi-net size and common water, condensate, and duct connection locations for easier and more efficient installation. The cabinet is constructed of unpainted, G-60 galvanized steel. Large panels provide access to the fan/motor compart-ment and the compressor/control compartment. The interiors of• Because of the simple design of the McQuay condensing unit, installation is quick, simple, and very little maintenance is required. Note: For further information on a complete air-cooled split system, refer to Catalog 580 (Destiny Indoor Air Handlers). Agency Listed Nomenclature Note: For larger size units (greater than 20 ton), refer to

Look for the 7th and 8th digits, or maybe 8th and 9th digits, of the model number. It will be a number divisible by 6 or 12, and represents the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU, and 48 divided by 12 equals 4, so the data plate below indicates the system is 4 tons.Find Us. McQuay Air-conditioning Limited (+852) 2893 6261; Unit 901~905, 9/F,Elite Centre, 22 Hung To Road, Kwun Tong, Kowloon,Hong KongMcQuay R-410A condensing units are available with EERs that exceed ASHRAE 90.1-2004. R-407C inevitably forces the unit to be significantly less efficient or more expensive, while R-410A reduces energy costs. R-410A refrigerant components are always evenly mixed, which is not true for R-407C.Instagram:https://instagram. joy risker murdermer contents crosswordroad closures on i 80 in wyomingdanny pintauro net worth The Skyline® air handling unit is designed to meet or exceed these demands. In addition to our patented construction, it features a durable, weathertight cabinet that promotes long life of your air handler. Skyline® also combats air contamination with micro-filtration, bacteria-defeating UV lights, mold-resistant drain pans, and anti ... garry's mod how to make a player modelbarberton motor vehicle bureau York/Quantech – Johnson Controls. Our literature library of data sheets, manuals, & engineering specs is constantly growing. If you need finding product literature call us at 214-321-4200. hamilton county sessions court tn HVAC Technician: Steven S. McQuay - WSC087-BAAA Water-Cooled (Semi-Hermetic) - 460V / 480V / 3-Phase / 60Hz - 400 Ton Capacity. Ask Your Own HVAC Question. WSC087-BAABC is the model number.Often used in conjunction with coils in air handlers, chillers receive warm fluid from the air handler coil or process load, lower the temperature of the fluid, then a pump returns the fluid to the air handler coil or process. Chillers come in two main varieties: air-cooled and water-cooled. An air cooled chiller rejects the heat absorbed from ...